Fractal geometry of culprit coronary plaque images within optical coherence tomography in patients with acute coronary syndrome vs stable angina pectoris

Heart Vessels. 2024 Aug 22. doi: 10.1007/s00380-024-02439-w. Online ahead of print.

Abstract

The main cause of acute coronary syndrome (ACS) is plaque rupture and thrombus formation. However, it has not been fairly successful to identify vulnerable plaque to rupture using conventional parameters of intravascular imaging modalities. Fractal analysis is one of the mathematical models to examine geometrical features of picture image using a specific parameter called as fractal dimension (FD) which suggests geometric complexity of the image. This study examined FD of the optical coherence tomography (OCT)-derived images of the culprit plaque in patients with ACS vs stable angina pectoris (SAP) to evaluate the feasibility of FD for identifying vulnerable coronary plaques prone to provoke ACS distinguished from stable plaques only provoking SAP. We examined 65 cases (34 ACS patients, 31 SAP patients) in which the culprit lesion was imaged by OCT before percutaneous coronary intervention in patients with ACS and SAP. The culprit plaque lesion in the ACS group had a significantly larger mean lipid arc (203.8 ± 39.4° vs 152.3 ± 34.5°, p < 0.001) and a larger lipid plaque length (12.6 ± 5.1 mm vs 7.7 ± 2.7 mm, p < 0.001) and a thinner fibrous cap thickness (75.3 ± 22.3 μm vs 134.8 ± 53.2 μm, p < 0.001) than those in the SAP group. The prevalence of OCT-derived macrophage infiltration (Mph) in the entire culprit coronary vessel as well as that of the OCT-derived thin-cap fibroatheroma (TCFA) at the culprit lesion were significantly greater in the ACS group than those in the SAP group, respectively (Mph: 61.8% vs 35.5%, p = 0.048; TCFA: 44.1% vs 6.4%, p < 0.001). The FD of culprit plaque in the ACS group was significantly greater than in the SAP group (2.401 ± 0.073 vs 2.341 ± 0.051, p < 0.001). In multivariate regression analysis, the presence of Mph was a significant determinant of FD (regression coefficient estimate 0.049, CI 0.018-0.079, p = 0.002). The FD of OCT-derived image of culprit coronary plaque in the ACS group was significantly greater than that in the SAP group, indicating that the culprit plaque in ACS were structurally more complex. Therefore, fractal analysis of coronary OCT images might be clinically useful for identifying coronary plaques prone to provoke ACS.

Keywords: Acute coronary syndrome; Coronary artery disease; Coronary plaque characteristics; Fractal analysis; Optical coherence tomography.