Abstract

Background: Set-up errors are an undesirable part of the radiation treatment process. The goal of online imaging is to increase treatment accuracy by reducing the set-up errors. This study aimed to determine the daily variation of patient set-up uncertainties and planning target volume (PTV) margins for head and neck cancer patients using pre-treatment verification by mega voltage cone-beam computed tomography (MV-CBCT).

Materials and methods: This retrospective study was internal record base of head and neck (H&N) cancer patients treated with definitive radiotherapy, adjuvant radiotherapy, and hypo-fractionated radiotherapy at our institution since the implementation of HalcyonTM 2.0 machine (Varian, US). Errors collected from each patient setup were recorded and evaluated for each direction [medio-lateral (ML), supero-inferior (SI), antero-posterior (AP)] discretely. For each patient, the systematic error (∑) and random error (σ) were collected. Clinical target volume (CTV) to planning target volume (PTV) margin was calculated using International Commission on Radiation Units and Measurements (ICRU) 62 ( PTV margin = ( Σ 2 + σ 2 ) ), Stroom's (PTV margin = 2∑ + 0.7σ), and Van Herk's (PTV margin = 2.5∑ + 0.7σ) formula.

Results: A total of 7900 pre-treatment CBCT scans of 301 patients were analyzed and a total of 23,000 error measurements in the ML, SI, and AP directions were recorded. For all of our H&N cancer patients, the CTV to PTV margin, calculated from the van Herk formula for the head and neck patients was 0.49 mm in the anteroposterior axis.

Conclusions: An isometric PTV margin of 5 mm may be considered safe if daily imaging is not being done. In case daily online pretreatment imaging is being utilized, further reduction of PTV margin is possible.

Keywords: imaging; planning target volume; radiotherapy; set up errors.