A case of repeated stent fracture

Oxf Med Case Reports. 2024 Jul 21;2024(7):omae075. doi: 10.1093/omcr/omae075. eCollection 2024 Jul.

Abstract

Stent fracture is one of the complications of drug-eluting stent implantation. An 84-year-old man underwent coronary angiography for unstable angina. He had diffuse severe stenosis and calcified plaque in the left anterior descending artery and underwent percutaneous coronary intervention (PCI) in the left anterior descending artery for severe stenosis with chest pain. Thereafter, two subsequent stent fractures occurred, so the patient underwent another PCI to cover them. However, a stent fracture was found again one year later. The patient was asymptomatic and PCI was avoided due to the risk of further stent fracture. When a stent fracture occurs, it is important to provide appropriate treatment according to the anatomical findings of the vessel, symptoms and the presence of ischemia.

Keywords: drug-eluting stent; everolimus-eluting stent; percutaneous coronary intervention; stent fracture.