Urgent Candy-Plug technique for distal false lumen occlusion in chronic aortic dissection

J Vasc Surg. 2024 Nov;80(5):1418-1424.e1. doi: 10.1016/j.jvs.2024.07.024. Epub 2024 Jul 17.

Abstract

Objective: This study aimed to assess the impact of urgency on early and midterm outcomes of the Candy-Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection.

Methods: The CP registry was reviewed, and patients were categorized into elective and urgent/emergent groups for analysis. End points included technical success, clinical success, early (30-day) computed tomography angiography findings, early (30-day) mortality, adverse events, and aortic remodeling in patients with available computed tomography angiography follow-up and reintervention.

Results: A total of 155 patients received a custom-made CP, of whom 32 patients (44% male, mean age 61 ± 9 years) were treated urgently and 123 patients (63% male, mean age 62 ± 11 years) electively. The primary CP rate was higher in the urgent group (28/32, 88%, in the urgent group vs 96/123, 78%, in the elective group, P = .051). The mean contrast volume was higher in the urgent group (157 ± 56 mL in the urgent group vs 130 ± 71 mL in the elective group, P = .017). Technical success was achieved in all patients in both groups. Clinical success was achieved in 25 of 32 (78%) patients in the urgent group vs 113 and 123 (92%) in the elective group (P = .159). The early mortality rate was 13% (4 of 32 patients) in the urgent group vs 1% (1 of 123 patients) in the elective group (P = .120). There was no statistically significant difference regarding the early adverse events between the urgent and elective CP groups. Early aortic-related reinterventions were required in 6 of 32 (19%) patients in the urgent group vs 6 of 123 (5%) in the elective group (P = .094). Thoracic aortic aneurysm sac regression was lower in the urgent group (5/28, 18%, in the urgent group vs 63/114, 55%, in the elective group, P = .001). Stable thoracic aortic aneurysm sac was higher in the urgent group (22/28, 79%, in the urgent group vs 47/114, 41%, in the elective group, P = .000). An increase in thoracic aortic aneurysm sac occurred in 1 of 28 (4%) patients in the urgent group vs 4 of 114 (4%) patients in the elective group (P = .096).

Conclusions: The urgent use of the CP technique for distal FL occlusion in aortic dissection was feasible and effective. The decrease in aortic FL sac diameter may be affected by the urgent use of CP due to limited sizing availability. However, it achieved a high rate of aortic remodeling.

Keywords: Aorta; Aortic dissection; Aortic remodeling; Embolization; Endovascular; False lumen; Repair; TEVAR.

MeSH terms

  • Aged
  • Aortic Aneurysm, Thoracic* / diagnostic imaging
  • Aortic Aneurysm, Thoracic* / mortality
  • Aortic Aneurysm, Thoracic* / surgery
  • Aortic Dissection* / diagnostic imaging
  • Aortic Dissection* / mortality
  • Aortic Dissection* / surgery
  • Aortography / methods
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Blood Vessel Prosthesis Implantation* / mortality
  • Chronic Disease
  • Computed Tomography Angiography*
  • Elective Surgical Procedures
  • Emergencies
  • Endovascular Procedures* / adverse effects
  • Endovascular Procedures* / instrumentation
  • Endovascular Procedures* / mortality
  • Female
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications / etiology
  • Prosthesis Design
  • Registries*
  • Retrospective Studies
  • Risk Factors
  • Stents
  • Time Factors
  • Treatment Outcome
  • Vascular Remodeling