Immune System Dose With Proton Versus Photon Radiotherapy for Treatment of Locally Advanced NSCLC

Int J Part Ther. 2024 Apr 23:12:100016. doi: 10.1016/j.ijpt.2024.100016. eCollection 2024 Jun.

Abstract

Purpose: Emerging data have illuminated the impact of effective radiation dose to immune cells (EDIC) on outcomes in patients with locally advanced, unresectable non-small cell lung cancer (NSCLC) treated with intensity-modulated radiotherapy (IMRT). Hypothesizing that intensity-modulated proton therapy (IMPT) may reduce EDIC versus IMRT, we conducted a dosimetric analysis of patients treated at our institution.

Materials and methods: Data were retrospectively collected for 12 patients with locally advanced, unresectable NSCLC diagnosed between 2019 and 2021 who had physician-approved IMRT and IMPT plans. Data to calculate EDIC from both Jin et al (PMID: 34944813) and Ladbury et al's (PMID: 31175902) models were abstracted. Paired t tests were utilized to compare the difference in mean EDIC between IMPT and IMRT plans.

Results: IMPT decreased EDIC for 11 of 12 patients (91.7%). The mean EDIC per the Jin model was significantly lower with IMPT than IMRT (3.04 GyE vs 4.99 Gy, P < .001). Similarly, the mean EDIC per the Ladbury model was significantly lower with IMPT than IMRT (4.50 GyE vs 7.60 Gy, P < .002). Modeled 2-year overall survival was significantly longer with IMPT than IMRT (median 71% vs 63%; P = .03).

Conclusion: IMPT offers a statistically significant reduction in EDIC compared to IMRT. Given the emergence of EDIC as a modifiable prognostic factor in treatment planning, our dosimetric study highlights a potential role for IMPT to address an unmet need in improving oncologic outcomes in patients with locoregionally advanced NSCLC.

Keywords: EDIC; NSCLC; Photon; Proton.