Abstract

Objective: Computed tomography (CT)/magnetic resonance imaging (MRI) Liver Imaging Reporting and Data System (LI-RADS, LR) category 5 has high specificity and modest sensitivity for diagnosis of hepatocellular carcinoma (HCC). The purpose of this study was to compare the diagnostic performance of LR-5 vs combined LR-4 and LR-5 (LR-4/5) for HCC diagnosis.

Methods: MEDLINE and EMBASE databases through January 03, 2023 were searched for studies reporting the performance of LR-5 and combined LR-4/5 for HCC diagnosis, using CT/MRI LI-RADS version 2014, 2017, or 2018. A bivariate random-effects model was used to calculate the pooled per-observation diagnostic performance. Subgroup analysis was performed based on imaging modalities and type of MRI contrast material.

Results: Sixty-nine studies (15,108 observations, 9928 (65.7%) HCCs) were included. Compared to LR-5, combined LR-4/5 showed significantly higher pooled sensitivity (83.0% (95% CI [80.3-85.8%]) vs 65.7% (95% CI [62.4-69.1%]); p < 0.001), lower pooled specificity (75.0% (95% CI [70.5-79.6%]) vs 91.7% (95% CI [90.2-93.1%]); p < 0.001), lower pooled positive likelihood ratio (3.60 (95% CI [3.06-4.23]) vs 6.18 (95% CI [5.35-7.14]); p < 0.001), and lower pooled negative likelihood ratio (0.22 (95% CI [0.19-0.25]) vs 0.38 (95% CI [0.35-0.41]) vs; p < 0.001). Similar results were seen in all subgroups.

Conclusions: Our meta-analysis showed that combining LR-4 and LR-5 would increase sensitivity but decrease specificity, positive likelihood ratio, and negative likelihood ratio. These findings may inform management guidelines and individualized management.

Clinical relevance statement: This meta-analysis estimated the magnitude of changes in the sensitivity and specificity of imaging criteria when LI-RADS categories 4 and 5 were combined; these findings can inform management guidelines and individualized management.

Key points: There is no single worldwide reporting system for liver imaging, partly due to regional needs. Combining LI-RADS categories 4 and 5 increased sensitivity and decreased specificity and positive and negative likelihood ratios. Changes in the sensitivity and specificity of imaging criteria can inform management guidelines and individualized management.

Keywords: Computed tomography; Contrast media; Diagnosis; Liver neoplasms; Magnetic resonance imaging.

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Carcinoma, Hepatocellular* / diagnostic imaging
  • Contrast Media
  • Humans
  • Liver / diagnostic imaging
  • Liver / pathology
  • Liver Neoplasms* / diagnostic imaging
  • Magnetic Resonance Imaging* / methods
  • Multimodal Imaging / methods
  • Radiology Information Systems
  • Sensitivity and Specificity*
  • Tomography, X-Ray Computed* / methods

Substances

  • Contrast Media