Usability of an Automated System for Real-Time Monitoring of Shared Decision-Making for Surgery: Mixed Methods Evaluation

JMIR Hum Factors. 2024 Apr 10:11:e46698. doi: 10.2196/46698.

Abstract

Background: Improving shared decision-making (SDM) for patients has become a health policy priority in many countries. Achieving high-quality SDM is particularly important for approximately 313 million surgical treatment decisions patients make globally every year. Large-scale monitoring of surgical patients' experience of SDM in real time is needed to identify the failings of SDM before surgery is performed. We developed a novel approach to automating real-time data collection using an electronic measurement system to address this. Examining usability will facilitate its optimization and wider implementation to inform interventions aimed at improving SDM.

Objective: This study examined the usability of an electronic real-time measurement system to monitor surgical patients' experience of SDM. We aimed to evaluate the metrics and indicators relevant to system effectiveness, system efficiency, and user satisfaction.

Methods: We performed a mixed methods usability evaluation using multiple participant cohorts. The measurement system was implemented in a large UK hospital to measure patients' experience of SDM electronically before surgery using 2 validated measures (CollaboRATE and SDM-Q-9). Quantitative data (collected between April 1 and December 31, 2021) provided measurement system metrics to assess system effectiveness and efficiency. We included adult patients booked for urgent and elective surgery across 7 specialties and excluded patients without the capacity to consent for medical procedures, those without access to an internet-enabled device, and those undergoing emergency or endoscopic procedures. Additional groups of service users (group 1: public members who had not engaged with the system; group 2: a subset of patients who completed the measurement system) completed user-testing sessions and semistructured interviews to assess system effectiveness and user satisfaction. We conducted quantitative data analysis using descriptive statistics and calculated the task completion rate and survey response rate (system effectiveness) as well as the task completion time, task efficiency, and relative efficiency (system efficiency). Qualitative thematic analysis identified indicators of and barriers to good usability (user satisfaction).

Results: A total of 2254 completed surveys were returned to the measurement system. A total of 25 service users (group 1: n=9; group 2: n=16) participated in user-testing sessions and interviews. The task completion rate was high (169/171, 98.8%) and the survey response rate was good (2254/5794, 38.9%). The median task completion time was 3 (IQR 2-13) minutes, suggesting good system efficiency and effectiveness. The qualitative findings emphasized good user satisfaction. The identified themes suggested that the measurement system is acceptable, easy to use, and easy to access. Service users identified potential barriers and solutions to acceptability and ease of access.

Conclusions: A mixed methods evaluation of an electronic measurement system for automated, real-time monitoring of patients' experience of SDM showed that usability among patients was high. Future pilot work will optimize the system for wider implementation to ultimately inform intervention development to improve SDM.

International registered report identifier (irrid): RR2-10.1136/bmjopen-2023-079155.

Keywords: data collection; electronic data collection; mixed methods; mobile phone; patient participation; patient reported; patient-reported measure; real-time measurement; satisfaction; shared decision-making; surgery; usability.

MeSH terms

  • Adult
  • Benchmarking*
  • Books
  • Health Policy
  • Humans
  • Internet
  • Research Design*