Accelerometer-derived physical activity and the risk of death, heart failure, and stroke in patients with atrial fibrillation: a prospective study from UK Biobank

Br J Sports Med. 2024 Apr 2;58(8):427-434. doi: 10.1136/bjsports-2023-106862.

Abstract

Objective: Data on cardiovascular outcomes according to objectively measured physical activity (PA) in patients with atrial fibrillation (AF) are scarce. This study explored the associations between PA derived from wrist-worn accelerometers and the risk of death, incident heart failure (HF), and incident stroke in patients with AF.

Methods: From 37 990 patients with AF in UK Biobank, 2324 patients with accelerometer data were included. Weekly moderate-to-vigorous PA (MVPA) duration was computed from accelerometer data. The primary outcome was all-cause mortality. Secondary outcomes were cardiovascular mortality, incident HF, and incident stroke. Restricted cubic splines estimated the dose-response associations between MVPA duration and the outcomes. The adjusted HRs (aHRs) of the outcomes according to adherence to PA standard guidelines (performing MVPA≥150 min/week) were also evaluated.

Results: The mean age was 66.9±6.2 years and 64.9% were male. During a median follow-up of 6.7 years, there were 181 all-cause deaths, 62 cardiovascular deaths, 225 cases of incident HF, and 91 cases of incident stroke; the overall incidence rate per 1000 patient-years was 11.76, 4.03, 15.16 and 5.99, respectively. There was a linear inverse dose-response relationship between MVPA (≥108 min/week) and all-cause mortality. Performing MVPA for 105-590 min/week was associated with a lower risk of HF than those with no measurable MVPA. The risk of stroke and cardiovascular mortality was not associated with MVPA. Performing guideline-adherent MVPA was related to a 30% lower risk of all-cause mortality (aHR: 0.70 (0.50-0.98), p=0.04) and 33% lower risk of HF (aHR 0.67 (0.49-0.93), p=0.02).

Conclusion: In patients with AF, accelerometer-derived PA data supports lower risks of all-cause mortality and HF according to a greater level of MVPA and adherence to PA guidelines. Regular MVPA should be encouraged in patients with AF as a part of integrated management.

Keywords: death; heart disease; physical activity.

MeSH terms

  • Accelerometry
  • Aged
  • Atrial Fibrillation* / epidemiology
  • Biological Specimen Banks
  • Exercise / physiology
  • Female
  • Heart Failure*
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Stroke*
  • UK Biobank