Redo aortic root surgery post-Ross procedure

Front Cardiovasc Med. 2023 Dec 12:10:1306445. doi: 10.3389/fcvm.2023.1306445. eCollection 2023.

Abstract

Background: Despite numerous advantages of the Ross procedure, it presents a risk of late autograft and right ventricular outflow tract conduit failure. This study aimed to analyze the outcomes of autograft dysfunction reoperations using autograft-sparing and root replacement techniques.

Methods: Between 2015 and 2023, 49 patients underwent redo root surgery in our institution. Autograft valve-sparing procedures (VSP) were performed in 20 cases and the Bentall procedure (BP) in 29 patients. The short and long-term clinical outcomes along with echocardiographic results of VSP and BP were investigated.

Results: Overall early mortality rate was 2.0% with no significant difference between the groups. Severe autograft valve insufficiency at the time of redo (OR 4.07, P = 0.03) and patient age (OR 1.07, P = 0.04) were associated with a valve replacement procedure instead of VSP. The median follow-up duration was 34 months. No late deaths occurred in either group. Freedom from VSP failure and aortic prosthesis dysfunction were 93.8% and 94.1% in the VSP and BP groups, respectively. No reoperations were necessary in either group.

Conclusion: Redo aortic root surgery can be safely performed in patients with autograft failure. Both root replacement and autograft valve-sparing procedures demonstrated acceptable results at mid-term follow-up. Early redo surgery pre-empting severe aortic insufficiency increases the likelihood of preservation of the dilated autograft valve.

Keywords: Bentall procedure; Ross procedure; pulmonary autograft; redo surgery; valve-sparing procedure.

Grants and funding

The author(s) declare financial support was received for the research, authorship, and/or publication of this article.