Nonclinical Cardiovascular Assessment of the Soluble Guanylate Cyclase Stimulator Vericiguat

J Pharmacol Exp Ther. 2023 Jul;386(1):26-34. doi: 10.1124/jpet.122.001368. Epub 2023 Apr 17.

Abstract

Vericiguat and its metabolite M-1 were assessed for proarrhythmic risk in nonclinical in vitro and in vivo studies. In vitro manual voltage-clamp recordings at room temperature determined the effect of vericiguat on human Ether-a-go-go Related Gene (hERG) K+ channels. Effects of vericiguat and M-1 on hERG K+, Nav1.5, hCav1.2, hKvLQT1/1minK, and hKv4.3 channels were investigated via automated voltage-clamp recordings at ambient temperature. Effects of vericiguat and M-1 on hERG K+ and Nav1.5 channels at pathophysiological conditions were explored via manual voltage-clamp recordings at physiologic temperature. Single oral doses of vericiguat (0.6, 2.0, and 6.0 mg/kg) were assessed for in vivo proarrhythmic risk via administration to conscious telemetered dogs; electrocardiogram (ECG) and hemodynamic parameters were monitored. ECG recordings were included in 4- and 39-week dog toxicity studies. In manual voltage-clamp recordings, vericiguat inhibited hERG K+-mediated tail currents in a concentration-dependent manner (20% threshold inhibitory concentration ∼1.9 µM). In automated voltage-clamp recordings, neither vericiguat nor M-1 were associated with biologically relevant inhibition (>20%) of hNav1.5, hCav1.2, hKvLQT1, and hKv4.3. No clinically relevant observations were made for hNav1.5 and hKvLQT1 under simulated pathophysiological conditions. Vericiguat was associated with expected mode-of-action-related dose-dependent changes in systolic arterial blood pressure (up to -20%) and heart rate (up to +53%). At maximum vericiguat dose, corrected QT (QTc) interval changes from baseline varied slightly (-6 to +1%) depending on correction formula. Toxicity studies confirmed absence of significant QTc interval changes. There was no evidence of an increased proarrhythmic risk from nonclinical studies with vericiguat or M-1. SIGNIFICANCE STATEMENT: There was no evidence of an increased proarrhythmic risk from in vitro and in vivo nonclinical studies with vericiguat or M-1. The integrated risk assessment of these nonclinical data combined with existing clinical data demonstrate administration of vericiguat 10 mg once daily in patients with heart failure with reduced ejection fraction is not associated with a proarrhythmic risk.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Dogs
  • Ether-A-Go-Go Potassium Channels
  • Heart Failure*
  • Heterocyclic Compounds, 2-Ring*
  • Humans
  • Pyrimidines
  • Soluble Guanylyl Cyclase / metabolism
  • Vasodilator Agents

Substances

  • Soluble Guanylyl Cyclase
  • vericiguat
  • Heterocyclic Compounds, 2-Ring
  • Pyrimidines
  • Vasodilator Agents
  • Ether-A-Go-Go Potassium Channels