Radiosurgery of limited brain metastases from primary solid tumor: results of the randomized phase III trial (NCT02355613) comparing treatments executed with a specialized or a C-arm linac-based platform

Radiat Oncol. 2023 Feb 7;18(1):28. doi: 10.1186/s13014-023-02216-5.

Abstract

Background: Comparative prospective data regarding different radiosurgery (SRS) modalities for treating brain metastases (BMs) from solid tumors are not available. To investigate with a single institute phase III randomized trial whether SRS executed with linac (Arm-B) is superior to a dedicated multi-source gamma-ray stereotactic platform (Arm-A).

Methods: Adults patients with 1-4 BMs from solid tumors up to 30 mm in maximum diameter were randomly assigned to arms A and B. The primary endpoint was cumulative incidence of symptomatic (grade 2-3) radionecrosis (CIRN). Secondary endpoints were local progression cumulative incidence (CILP), distant brain failure, disease-free survival (DFS), and overall survival (OS).

Results: A total of 251 patients were randomly assigned to Arm-A (121) or Arm-B (130). The 1-year RN cumulative incidence was 6.7% in whole cohort, 3.8% (95% CI 1.9-7.4%) in Arm-B, and 9.3% (95% CI 6.2-13.8%) in the Arm-A (p = 0.43). CIRN was influenced by target volume irradiated only for the Arm-A (p << 0.001; HR 1.36 [95% CI 1.25-1.48]). Symptomatic RN occurred in 56 cases at a median time of 10.3 months (range 1.15-54.8 months), 27 in the Arm-B at a median time of 15.9 months (range 4.9-54.8 months), and 29 in the Arm-A at a median time of 6.9 months (1.2-32.3 months), without statistically significant differences between the two arms. No statistically significant differences were recorded between the two arms in CILP, BDF, DFS or OS. The mean beam-on time to deliver SRS was 49.0 ± 36.2 min in Arm-A, and 3.1 ± 1.6 min in Arm-B.

Conclusions: Given the technical differences between the treatment platforms investigated in this single-institution study, linac-based SRS (Arm-B) did not lead to significantly lower grade 2-3 RN rates versus the multi-source gamma-ray system (Arm-A) in a population of patients with limited brain metastases of small volume. No significant difference in local control was observed between both arms. For Arm-B, the treatment delivery time was significantly lower than for Arm-A.

Trial registration: ClinicalTrials.gov Identifier NCT02355613.

Keywords: Brain metastases; Gamma Knife-radiosurgery; Linac-based radiosurgery; Radionecrosis; Radiosurgery; Randomized phase 3 trial.

Publication types

  • Randomized Controlled Trial
  • Clinical Trial, Phase III

MeSH terms

  • Adult
  • Brain Neoplasms* / secondary
  • Humans
  • Progression-Free Survival
  • Prospective Studies
  • Radiosurgery* / methods
  • Retrospective Studies
  • Treatment Outcome

Associated data

  • ClinicalTrials.gov/NCT02355613