Quantitation of cystic fibrosis triple combination therapy, elexacaftor/tezacaftor/ivacaftor, in human plasma and cellular lysate

J Chromatogr B Analyt Technol Biomed Life Sci. 2022 Dec 15:1213:123518. doi: 10.1016/j.jchromb.2022.123518. Epub 2022 Nov 3.

Abstract

The triple combination modulator therapy (ETI, elexacaftor (ELX), tezacaftor (TEZ), and ivacaftor (IVA)) is a recent advancement for the care of patients with cystic fibrosis. To aid in the development of clinical pharmacokinetics studies of this treatment, we developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for quantifying the component compounds in human plasma and cell lysate. This assay was optimized for small volumes (10 µL), uses stably labeled isotopes of the ETI compounds as internal standards, and employs a simple methanol protein precipitation method. Chromatography was performed on an ACE Excel C18, 2.1 × 50 mm, reversed phase analytical column, using a step or bump isocratic method, with mobile phases consisting of 0.1% formic acid in water for A, and 0.1% formic acid in acetonitrile for B. Analyte and internal standard detection was conducted with ESI positive ionization tandem mass spectrometry. The precursor/product transitions (m/z) monitored were 598.0/422.0 for ELX, 521.0/449.0 for TEZ, 393.0/172.0 for IVA, 601.0/422.0 for IS-ELX, 525.0/453.0 for IS-TEZ, and 399.0/178.0 for IS-IVA, respectively. The assay has a dynamic range of 10 to 10,000 ng/mL, with a mean coefficient of determination (r2, mean ± SD) of 0.9970 ± 0.0027 (ELX), 0.9989 ± 0.0004 (TEZ), 0.9981 ± 0.0003 (IVA), regardless of specimen matrix. The mean precision values for all calibration standards ranged from 0.0 to 10.8% (ELX), 0.0 to 6.7% (TEZ), and 0.2 to 5.6% (IVA), while the accuracy for calibration standards was within the range of -5.7 to 3.5% (ELX), -3.2 to 6.0% (TEZ), and -3.8 to 5.2% (IVA). Validation results demonstrated high accuracy (≤7.3, ≤9.8, ≤10.6% deviation) and high precision (≤11.5, ≤6.3, ≤11.0% CV) for the respective ETI quality control samples. This method provides a fully validated assay for ETI quantitation for use in clinical research.

Keywords: CFTR; Cystic Fibrosis; Elexacaftor; Ivacaftor; LC-MS/MS; Tezacaftor.

MeSH terms

  • Aminophenols
  • Benzodioxoles
  • Chromatography, Liquid
  • Cystic Fibrosis* / drug therapy
  • Humans
  • Tandem Mass Spectrometry / methods

Substances

  • ivacaftor
  • tezacaftor
  • formic acid
  • elexacaftor
  • Aminophenols
  • Benzodioxoles