Background and aims: Both single-balloon enteroscopy (SBE) and the novel motorized spiral enteroscopy (NMSE) are effective techniques for device-assisted enteroscopy (DAE). To date, no study has prospectively compared both modalities in suspected Crohn's disease (CD).
Methods: Patients with suspected CD undergoing either SBE or NMSE between March 2021 and December 2021 in a high-volume tertiary center were prospectively compared for technical success (ability to reach the lesion), diagnostic yield, depth of maximal insertion (DMI), procedure time, and total enteroscopy rates.
Results: One hundred seventy-seven patients (37.2% female; aged 7-75 years) with suspected CD underwent 201 DAEs. Technical success was 83% (SBE 81.5% vs NMSE 87.3%, P = .61) and impacted subsequent management in 92% (SBE 88.5% vs NMSE 97.8%, P = .2). Technical success with antegrade NMSE was significantly higher (81.4%) than antegrade SBE (33.3%, P = .007) for lesions in the proximal ileum and beyond. There was no significant difference in the diagnostic yield (SBE 80.8% vs NMSE 83.6%, P = .65). Median procedure time was significantly lower in both antegrade (NMSE, 40 minutes [range, 10-75]; SBE, 60 minutes [range, 20-180]; P < .0001) and retrograde (NMSE, 25 minutes [range, 20-60]; SBE, 60 minutes [range, 20-180]; P < .0001) NMSE. Median DMI was higher with antegrade NMSE (NMSE, 400 cm [range, 70-600]; SBE, 180 cm [range, 60-430]; P < .0001). The total enteroscopy rate was higher with NMSE (37% vs .7% with SBE, P < .0001). All adverse events were mild.
Conclusions: Both NMSE and SBE are safe and effective for small-bowel evaluation in suspected CD. NMSE is superior to SBE with regard to deeper small-bowel evaluation with complete small-bowel coverage and shorter procedure time.
Copyright © 2023 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.