Background: In the US, only 23% of lungs offered for transplantation are transplanted. Ex vivo lung perfusion (EVLP) allows for evaluation of additional donor lungs; its adoption has been limited by resources and expertise. Dedicated facilities with a centralized lung evaluation system (CLES) could expand access to EVLP.
Methods: In this unblinded, nonrandomized, traditional feasibility study, 7 US transplant centers referred lungs declined for standard transplantation to a dedicated EVLP facility, which utilized a CLES. EVLP was remotely monitored by the transplant teams. CLES lungs were matched with contemporaneous conventional static cold-preserved controls at each center.
Results: A total of 115 recipients were enrolled, and 66 received allografts from 63 donors after EVLP at the dedicated CLES facility. Forty-nine contemporaneous patients served as controls. Primary graft dysfunction grade 3 at 72 hours (PGD3-72 hours) was higher in the CLES group with 16 (24%) vs 2 (4%) in the control (common RD 95% CI, 0.07-0.32; p = 0.0009). All recipients survived to 30 days and 1-year survival was similar for both groups (92% controls vs 89% CLES; common RD 95% CI, -0.14-0.08; p = 0.58). Total preservation time, hospital and ICU lengths of stay, and time to first extubation were longer in the CLES group.
Conclusions: Remote ex vivo perfusion of lung allografts declined for conventional transplantation at a dedicated CLES facility is feasible and resulted in additional transplants. Recipients of allografts assessed with a CLES had a higher rate of PGD3-72 hours, but similar 30-day and 1-year outcomes compared to conventional lung recipients. (NCT02234128).
Keywords: EVLP; PGD3; cold ischemia time; donation after cardiac death; lung transplant.
Copyright © 2022 The Authors. Published by Elsevier Inc. All rights reserved.