Tissue-engineered cornea endothelial sheets (TECES), created using a biocompatible thin and transparent carrier with corneal endothelial cells, could alleviate the shortage of donor corneas and provide abundant functional endothelial cells. In our previous clinical trials, the effectiveness and safety of the acellular porcine corneal stroma (APCS) applied in lamellar keratoplasty have been confirmed. In this study, we optimized the method to cut APCS into multiple 20 μm ultrathin lamellae by a cryostat microtome and investigated the feasibility of TECES by seeding rabbit corneal endothelial cells (RCECs) on ultrathin APCS. Cell adhesion, proliferation, and functional gene expression of RCECs on tissue-culture plastic and APCS of different thicknesses were compared. The results indicated that ultrathin lamellae were superior in increasing cell viability and maintaining cell functions. Analyzing with histology, electron microscopy, and immunofluorescence, we found that RCECs cultured on 20 μm ultrathin APCS for 5 days grew into a confluent monolayer with a density of 3726 ± 223 cells/mm2 and expressed functional biomarkers Na+/K+-ATPase and zonula occludens. After 14 days, RCECs formed an early stage of Descemet's membrane-like structure by synthesizing collagen IV and laminin. Human corneal endothelial cells were also used to further validate the supportive effect of ultrathin APCS on cells. The resulting constructs were flexible and tough enough to implant into rabbits' anterior chambers through small incisions. TECES adhered to the posterior corneal stroma, and the thickness of cornea gradually reduced to normal after grafting. These results indicate that the ultrathin APCS can serve as a tissue engineering carrier and might be a suitable alternative for endothelial cells expansion in endothelial keratoplasty.
Keywords: acellular porcine corneal stroma; carrier; endothelial keratoplasty; tissue engineering; ultrathin.