Background: Transcatheter aortic valve replacement (TAVR) procedural success relies heavily on volumetric reconstruction imaging, particularly ECG-gated multi-detector row computed tomography. We postulated that single examination using fast low-angle shot (FLASH) dual source CT scanning (DS-CTA) could provide lower dose than ECG-gated CTA while maintaining the image quality.
Methods: In this single-centre cohort study, all patients who underwent ECG-gated and FLASH DS-CTA were evaluated. Volumetric reconstructions were performed for both ECG-gated and FLASH DS-CTA to obtain nonsagittal views of the structures. ECG-gated cardiac CT was obtained to evaluate the aortic annular size while FLASH DS-CTA was obtained to examine the aortic and iliac vasculature as part of TAVR imaging protocol. We evaluated measures of aortic annulus, coronaries and sinus of Valsalva using ECG-gated and FLASH DS-CTA scanning protocols. Image quality assessments were performed using aortic root region-of-interest signal-to-noise ratio.
Results: A total of 130 patients (mean age 81.5 ± 9.2 years, 46.2% female, and 99.2% white) underwent both ECG-gated CT and FLASH DS-CTA. There were excellent correlations between aortic annular area (R2 = 0.934) and aortic annular perimeter (R2 = 0.923) measured by the two protocols. Only 2 (1.5%) patients had >10% difference between aortic annular measurements by ECG-gated and FLASH DS-CTA, while none of the patients had a >10% difference between aortic annular perimeter measured by ECG-gated and FLASH DS-CT scans. There was no significant difference in signal-to-noise ratio between the two methods (mean difference 13.4; 95% CI -2.1-28.8, p = 0.09). There was significantly lower radiation dose for FLASH DS-CTA than ECG-gated CT scan (mean dose-length product difference 404.38; 95% CI 328.9-479.87, p <0.001). The measurements by the two scans led to the same transcatheter valve size selection in majority of the 128 (98.5%) patients by balloon expandable valve sizing recommendations and 130 (100%) of patients by self-expanding valve sizing recommendations.
Conclusion: Overall, FLASH DS-CTA and ECG-gated CT scans provided comparable image quality and aortic annular dimensions for pre-TAVR evaluation. DS-CTA additionally provided the necessary angiographic imaging of the aorta and peripheral access vessels while still maintaining a lower radiation dose. We propose that a single non-ECG gated FLASH DS-CTA could be utilized to provide all the necessary pre-TAVR imaging information without a gated CT scan.
Copyright © 2020 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.