Long-term clinical outcomes after single freeze cryoballoon ablation for paroxysmal atrial fibrillation: a 5-year follow-up

J Interv Card Electrophysiol. 2021 Jun;61(1):87-93. doi: 10.1007/s10840-020-00788-w. Epub 2020 May 29.

Abstract

Background: The second-generation cryoballoon ablation (CB-A) has been proven to be safe and effective for pulmonary vein (PV) isolation. Little is known regarding the long-term outcome following CB-A ablation for paroxysmal atrial fibrillation (AF). The aim of the study was to evaluate the freedom from atrial arrhythmias during a 5-year follow-up period among consecutive patients having undergone PV isolation with the CB-A for paroxysmal AF METHODS AND RESULTS: A total of 208 consecutive patients having undergone index PV isolation using CB-A (138 males, 66%; mean age 59.0 ± 12.6 years) were included in our retrospective analysis. Follow-up was based on outpatient clinic visits including Holter electrocardiograms. Recurrence of atrial tachyarrhythmias was defined as a symptomatic or documented episode of > 30 s. At a median follow-up of 62 months, freedom from atrial arrhythmias after a single procedure was achieved in 57.2% of patients. Multivariate analysis demonstrated that obesity, left atrial diameter, and duration of symptoms before AF ablation were independent predictors of ATas recurrences. Major complications occurred in 2.4% of patients.

Conclusions: The present study found a 5-year single-procedure success rate of 57.2% following CB-A ablation procedure. Obesity, higher LA dimensions, and longer duration of symptoms before ablation independently predicted the outcome.

Keywords: Atrial fibrillation; Catheter ablation; Cryoballoon; Paroxysmal.

MeSH terms

  • Atrial Fibrillation* / diagnostic imaging
  • Atrial Fibrillation* / surgery
  • Catheter Ablation*
  • Cryosurgery*
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Pulmonary Veins* / diagnostic imaging
  • Pulmonary Veins* / surgery
  • Recurrence
  • Retrospective Studies