Repeat Transcatheter Aortic Valve Replacement for Transcatheter Prosthesis Dysfunction

J Am Coll Cardiol. 2020 Apr 28;75(16):1882-1893. doi: 10.1016/j.jacc.2020.02.051.

Abstract

Background: Transcatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail.

Objectives: The authors sought to examine outcomes following redo-TAVR.

Methods: The Redo-TAVR registry collected data on consecutive patients who underwent redo-TAVR at 37 centers. Patients were classified as probable TAVR failure or probable THV failure if they presented within or beyond 1 year of their index TAVR, respectively.

Results: Among 63,876 TAVR procedures, 212 consecutive redo-TAVR procedures were identified (0.33%): 74 within and 138 beyond 1 year of the initial procedure. For these 2 groups, TAVR-to-redo-TAVR time was 68 (38 to 154) days and 5 (3 to 6) years. The indication for redo-TAVR was THV stenosis in 12 (16.2%) and 51 (37.0%) (p = 0.002) and regurgitation or combined stenosis-regurgitation in 62 (83.8%) and 86 (62.3%) (p = 0.028), respectively. Device success using VARC-2 criteria was achieved in 180 patients (85.1%); most failures were attributable to high residual gradients (14.1%) or regurgitation (8.9%). At 30-day and 1-year follow-up, residual gradients were 12.6 ± 7.5 mm Hg and 12.9 ± 9.0 mm Hg; valve area 1.63 ± 0.61 cm2 and 1.51 ± 0.57 cm2; and regurgitation ≤mild in 91% and 91%, respectively. Peri-procedural complication rates were low (3 stroke [1.4%], 7 valve malposition [3.3%], 2 coronary obstruction [0.9%], 20 new permanent pacemaker [9.6%], no mortality), and symptomatic improvement was substantial. Survival at 30 days was 94.6% and 98.5% (p = 0.101) and 83.6% and 88.3% (p = 0.335) at 1 year for patients presenting with early and late valve dysfunction, respectively.

Conclusions: Redo-TAVR is a relatively safe and effective option for selected patients with valve dysfunction after TAVR. These results are important for applicability of TAVR in patients with long life expectancy in whom THV durability may be a concern.

Keywords: durability; transcatheter aortic valve replacement; transcatheter heart valve; valve-in-valve.

MeSH terms

  • Aged
  • Aortic Valve / surgery
  • Aortic Valve Insufficiency* / diagnosis
  • Aortic Valve Insufficiency* / epidemiology
  • Aortic Valve Insufficiency* / etiology
  • Aortic Valve Insufficiency* / surgery
  • Aortic Valve Stenosis / surgery*
  • Equipment Failure Analysis
  • Female
  • Global Health
  • Heart Valve Prosthesis / adverse effects*
  • Humans
  • Male
  • Outcome Assessment, Health Care
  • Postoperative Complications* / diagnosis
  • Postoperative Complications* / epidemiology
  • Postoperative Complications* / surgery
  • Registries / statistics & numerical data
  • Reoperation* / instrumentation
  • Reoperation* / methods
  • Reoperation* / statistics & numerical data
  • Survival Analysis
  • Symptom Assessment / statistics & numerical data
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Transcatheter Aortic Valve Replacement* / instrumentation
  • Transcatheter Aortic Valve Replacement* / methods