Background: Little is known about late outcomes after transcatheter aortic valve replacement (TAVR) in dialysis patients.Methods and Results:We enrolled 25 dialysis patients (mean age 76.5 years; mean STS score 14.7%; men 60.0%) with aortic valve stenosis undergoing TAVR at our institute. Cardiovascular mortality and stroke were defined according to the VARC-2 criteria, and major adverse cardiac and cerebrovascular events (MACCE) were investigated. Twenty-three patients (92.0%) were discharged, and the median hospital stay after TAVR was 9 days (IQR, 7.5-11 days). Mortality at 30 days was not observed. The overall survival rate at 1 and 3 years were 80.0% and 55.7%, respectively (follow-up period, 879±493 days; range, 40-1,826 days). At 1 and 3 years, rates of freedom from cardiovascular mortality, disabling stroke, and MACCE were 100% and 83.0%, 91.2% and 84.7%, and 69.8% and 39.9%, respectively. Three patients required redo-TAVR for valve dysfunction at 23, 36, and 38 months after the first TAVR, respectively (The rate of freedom from severe structural valve deterioration at 1 and 3 years was 100% and 85.9%, respectively).
Conclusions: Satisfactory in-hospital outcomes were achieved in dialysis patients after TAVR. Various problems, however, such as complications particular to dialysis patients and valve durability, remained at midterm follow-up. Further studies are recommended to solve these problems, and prudent preoperative assessments should be mandatory.
Keywords: Aortic stenosis; Dialysis; Transcatheter aortic valve replacement/implantation.