Diffusion-weighted magnetic resonance imaging for detection of postoperative intracranial pyogenic abscesses in neurosurgery

Acta Neurochir (Wien). 2019 May;161(5):985-993. doi: 10.1007/s00701-019-03875-8. Epub 2019 Mar 26.

Abstract

Background: Diffusion-weighted magnetic resonance imaging (MRI-DWI) is the modality of choice for detecting intracranial abscesses; however, it is unclear whether prior brain surgery has an influence on its diagnostic value. Thus, we assessed the robustness of MRI-DWI and determination of an ADC cutoff value for detecting intracranial abscesses in patients who underwent brain surgery.

Methods: We retrospectively evaluated 19 patients prior to surgery for postoperative supratentorial parenchymal abscesses by means of MRI-DWI. Forty randomly selected patients with routine postoperative MRI-DWI were used for comparative analyses. Clinical and serum biomarkers (C-reactive protein, interleukin-6, white blood cell count) as well as from results of early postoperative imaging findings (computed tomography and/or MRI scan) were recorded. Additionally, ADC values, T1±gadolinium, and T2/fluid-attenuated inversion recovery sequences were investigated.

Results: After initial surgery, early postoperative control imaging showed evidence of hemorrhage and/or hemostatic agents within the resection cavity in 10/19 patients of the abscess group and in 16/40 patients of the control group. No postoperative ischemia was detected. Neither hemostatic agents nor blood affected the mean ADC values in both the reference group (blood 2.96 ± 0.22 × 10-3 mm2/s vs. no blood 2.95 ± 0.26 × 10-3 mm2/s, p = 0.076) and in the abscess group (blood 0.87 ± 0.07 × 10-3 mm2/s vs. no blood 0.76 ± 0.06 × 10-3 mm2/s, p = 0.128). The mean ADC value within the resection cavity was significantly lower in the abscess group (1.5 T 0.88 ± 0.41 vs. 2.88 ± 0.20 × 10-3 mm2/s, p < .01; 3.0 T 0.75 ± 0.24 vs. 3.02 ± 0.26 × 10-3 mm2/s, p < 0.01). The optimal ADC cut-off for the differentiation of an abscess from normal postoperative findings was found at 1.87 × 10-3 mm2/s (area-under-the-curve 1.0, sensitivity = 100%, specificity = 100%). Moreover, no differences between the abscess patients and the control group were seen with respect to the analyzed serum biomarkers.

Conclusion: MRI-DWI provides a robust tool to discriminate postoperative abscess formation from normal postoperative changes.

Keywords: Apparent diffusion coefficient; Diffusion-weighted MRI; Neurosurgery; Pyogenic intracranial abscess; Revision surgery; Serum biomarker.

MeSH terms

  • Adult
  • Aged
  • Biomarkers / blood
  • Brain Abscess / blood
  • Brain Abscess / diagnostic imaging*
  • Brain Abscess / etiology
  • Diffusion Magnetic Resonance Imaging / methods*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Neurosurgical Procedures / adverse effects*
  • Postoperative Complications / blood
  • Postoperative Complications / diagnostic imaging*
  • Postoperative Complications / etiology

Substances

  • Biomarkers