Objectives: Fissure integrity (FI) plays a key role in selecting patients for interventional emphysema therapy. We investigated its interference with automated lobar segmentation in quantitative computed tomography (CT) and emphysema distribution.
Methods: CT was available for 50 patients with chronic obstructive pulmonary disease (COPD). Lobe segmentation was performed fully automated by software and corrected manually. FI was evaluated visually using a %-scale. The influence of FI on emphysema ratio (ER=percentage of lung volume with density values<-950 HU), mean lung density (MLD), emphysema and total volume of adjacent lobes was analyzed. Lobe-based results were compared with respect to FI.
Results: Differences in ER in adjacent lobes for complete vs. incomplete fissures were 12.4% for the right horizontal, 0.2% and 3% for the right oblique and 4.4% for the left oblique fissure (all p>0.05). Results for emphysema comparing automated vs. manually corrected segmentation exceeded clinically acceptable values, but were not significantly affected by FI (p>0.05). The widest limits of agreement for ER and MLD were noted in the right middle lobe ([-14, 17.4%], [-22.4, 32.4 Hounsfield Units]).
Conclusions: Automated lobe segmentation and emphysema distribution are not significantly affected by FI. Manual correction of automated lobar segmentation is still recommended in severe emphysema.
Keywords: Chronic obstructive pulmonary disease; Collateral ventilation; Emphysema; Fissure integrity; Quantitative computed tomography.
Copyright © 2017 Elsevier B.V. All rights reserved.