Indirect MRI of 17 o-labeled water using steady-state sequences: Signal simulation and preclinical experiment

J Magn Reson Imaging. 2018 May;47(5):1373-1379. doi: 10.1002/jmri.25848. Epub 2017 Aug 31.

Abstract

Background: Few studies have been reported for T2 -weighted indirect 17 O imaging.

Purpose/hypothesis: To evaluate the feasibility of steady-state sequences for indirect 17 O brain imaging.

Study type: Signal simulation, phantom measurements, and prospective animal experiments were performed in accordance with the institutional guidelines for animal experiments.

Population/subjects/phantom/specimen/animal model: Signal simulations of balanced steady-state free precession (bSSFP) were performed for concentrations of 17 O ranging from 0.037-1.600%. Phantom measurements with concentrations of 17 O water ranging from 0.037-1.566% were also conducted. Six healthy beagle dogs were scanned with intravenous administration of 20% 17 O-labeled water (1 mL/kg).

Field strength/sequence: Dynamic 3D-bSSFP scans were performed at 3T MRI. 17 O-labeled water was injected 60 seconds after the scan start, and the total scan duration was 5 minutes.

Assessment: Based on the result of signal simulation and phantom measurement, signal changes in the beagle dogs were measured and converted into 17 O concentrations.

Statistical tests: The 17 O concentrations were averaged for every 15 seconds, and compared to the baseline (30-45 sec) with Dunnett's multiple comparison tests.

Results: Signal simulation revealed that the relationships between 17 O concentration and the natural logarithm of relative signals were linear. The intraclass correlation coefficient between relative signals in phantom measurement and signal simulations was 0.974. In the animal experiments, significant increases in 17 O concentration (P < 0.05) were observed 60 seconds after the injection of 17 O. At the end of scanning, mean respective 17 O concentrations of 0.084 ± 0.026%, 0.117 ± 0.038, 0.082 ± 0.037%, and 0.049 ± 0.004% were noted for the cerebral cortex, cerebellar cortex, cerebral white matter, and ventricle.

Data conclusion: Dynamic steady-state sequences were feasible for indirect 17 O imaging, and absolute quantification was possible. This method can be applied for the measurement of permeability and blood flow in the brain, and for kinetic analysis of cerebrospinal fluid.

Level of evidence: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1373-1379.

Keywords: O-17; animal study; phantom measurement; signal simulation; steady state sequence.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Brain Mapping
  • Computer Simulation
  • Dogs
  • Image Interpretation, Computer-Assisted / methods*
  • Imaging, Three-Dimensional / methods
  • Kinetics
  • Magnetic Resonance Imaging*
  • Male
  • Oxygen
  • Oxygen Isotopes*
  • Phantoms, Imaging
  • Protons
  • Reproducibility of Results
  • Signal Processing, Computer-Assisted

Substances

  • Oxygen Isotopes
  • Protons
  • Oxygen