Stentless Bioprostheses for Aortic Valve Replacement in Octogenarians: The Influence of Coronary Artery Disease

Thorac Cardiovasc Surg. 2018 Jun;66(4):322-327. doi: 10.1055/s-0037-1604048. Epub 2017 Jul 4.

Abstract

Background: We sought to determine the long-term results of stentless biological heart valve replacement in octogenarians to find out whether coronary artery disease or the coronary artery bypass grafting (CABG) procedure itself influences survival in these aged patients.

Methods: From 4,012 patients undergoing aortic valve replacement (AVR) with a stentless prosthesis (Freestyle, Medtronic) at a single center, 721 patients were older than 80 years. They had a mean age of 83 ± 2 (2,320 patient years), the male/female ratio was 42:58, NYHA (New York Heart Association) class I and II was prevalent in 22.8%, preoperative atrial fibrillation (AF) in 20.6%, coronary artery disease in 56.1%, mitral valve disease in 12.5%, and aortic disease in 3.5%. Follow-up included a total of 11,546 patient years (mean follow-up time: 74 ± 53 months); follow-up mortality data were 96.3% complete.

Results: In these aged patients, 30-day mortality in the isolated AVR group (10.3%) was similar to that in the AVR + CABG group (13.4%). Although long-term survival (15 years) in the octogenarian population is low (9% in the AVR group and 6% in the AVR + CABG group), it was not different (p = 0.191) between patients with and without coronary artery disease. The stroke rate and the myocardial infarction rate, respectively, in the AVR + CABG group (0.43%/100 patient years and 0.17%/100 patient years) were only insignificantly higher than that in the isolated AVR group (each 0.01%/100 patient years). The actuarial freedom from reoperation was 99% in both the groups.

Conclusion: Use of the Freestyle stentless valve prosthesis for AVR is feasible also in octogenarians. The existence of coronary artery disease leads to concomitant bypass surgery, but not a higher level of perioperative or long-term mortality.

MeSH terms

  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Bioprosthesis*
  • Coronary Artery Bypass* / adverse effects
  • Coronary Artery Bypass* / mortality
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / physiopathology
  • Coronary Artery Disease / surgery*
  • Female
  • Heart Valve Diseases / diagnostic imaging
  • Heart Valve Diseases / mortality
  • Heart Valve Diseases / physiopathology
  • Heart Valve Diseases / surgery*
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Proportional Hazards Models
  • Prosthesis Design
  • Risk Factors
  • Time Factors
  • Treatment Outcome