Fast and sensitive analysis of beta blockers by ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry

Biomed Chromatogr. 2017 Jul;31(7). doi: 10.1002/bmc.3911. Epub 2017 Jan 4.

Abstract

This paper presents a method for the determination of acebutolol, betaxolol, bisoprolol, metoprolol, nebivolol and sotalol in human serum by liquid-liquid extraction and ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry. After liquid-liquid extraction, beta blockers were separated on a reverse-phase analytical column (Acclaim RS 120; 100 × 2.1 mm, 2.2 μm). The total run time was 6 min for each sample. Linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery and sample stability were evaluated. The method was successfully applied to the therapeutic drug monitoring of 108 patients with hypertension. This method was also used for determination of beta blockers in 33 intoxicated patients.

Keywords: beta blockers; forensic toxicological screening; liquid chromatography; mass spectrometry; therapeutic drug monitoring.

MeSH terms

  • Adrenergic beta-Antagonists / blood*
  • Chromatography, High Pressure Liquid / methods*
  • Female
  • Humans
  • Limit of Detection
  • Male
  • Mass Spectrometry / methods*
  • Middle Aged
  • Reference Standards
  • Reproducibility of Results

Substances

  • Adrenergic beta-Antagonists