A Proton Transfer Reaction-Mass Spectrometer (PTR-MS) has been coupled to the outlet of a Field and Laboratory Emission Cell (FLEC), to measure volatile organic compounds (VOC) concentration during a sorption experiments (Rizk et al., this issue) [1]. The limits of detection of the PTR-MS for three VOCs are presented for different time resolution (2, 10 and 20 s). The mass transfer coefficient was calculated in the FLEC cavity for the different flow rates. The concentration profile obtained from a sorption experiment performed on a gypsum board and a vinyl flooring are also presented in comparison with the profile obtained for a Pyrex glass used as a material that do not present any sorption behavior (no sink). Finally, the correlation between the concentration of VOCs adsorbed on the surface of the gypsum board at equilibrium (Cse ) and the concentration of VOCs Ce measured in the gas phase at equilibrium is presented for benzene, C8 aromatics and toluene.