The safety and efficacy of LY2963016 insulin glargine (LY IGlar) and Lantus insulin glargine (IGlar), products with identical primary amino acid sequences, were assessed in subgroups of patients with type 1 (T1D, n = 452) or type 2 diabetes (T2D, n = 299) reporting prestudy IGlar treatment in 52-week open-label (ELEMENT-1) and 24-week double-blind (ELEMENT-2) studies. At randomization, patients transitioned from their prestudy IGlar to equivalent doses of LY IGlar or IGlar. Primary efficacy (change in glycated haemoglobin from baseline to 24 weeks), other efficacy and select safety outcomes of LY IGlar were compared with those of IGlar. Continuous data were analysed using analysis of covariance, categorical data by Fisher's exact test, and treatment comparisons for hypoglycaemia by Wilcoxon test. No statistically significant treatment differences were identified for efficacy and safety outcomes except for weight change (T1D), overall incidence of detectable insulin antibodies (T2D), and serious adverse events (T2D). These differences were neither consistently observed across both studies nor observed in the total study populations, and their magnitude suggests they were not clinically meaningful. LY IGlar and IGlar show similar efficacy and safety profiles in patients reporting prestudy IGlar treatment.
Keywords: LY2963016 insulin glargine; biosimilar insulin; insulin glargine.
© 2016 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.