[Related factors of hemodynamic damage after carotid artery stenting]

Beijing Da Xue Xue Bao Yi Xue Ban. 2015 Oct 18;47(5):804-8.
[Article in Chinese]

Abstract

Objective: To analyze correlation factors of hemodynamic damage after carotid artery stenting.

Methods: In this study, 66 cases (71 lesions) who undertook carotid artery stenting were collected and the correlation factors of hemodynamic damage were analyzed.

Results: Hemodynamic damage emerged in 23 cases (32.4%), of which, 11.3% developed hypotension. The distance between bifurcation and lesions (P=0.0020), plaque distribution (P=0.0002), plaque character (P=0.0019), post-dilation (P=0.0026) were associated with hemodynamic damage by single factor analysis. However, only eccentric plaque (P=0.0153) and calcified plaque (P=0.0097) were associated with hemodynamic damage by multiple factors analysis. All the patients could reach stable circulation by drugs during operation, and no cerebral ischemic events (transient ischemic attack or stroke) and cardiovascular ischemic events happened.

Conclusion: The distance between bifurcation and lesions, eccentric plaques, calcified plaques are correlation factors of hemodynamic damage.

MeSH terms

  • Carotid Arteries*
  • Carotid Artery, Common
  • Carotid Stenosis / pathology*
  • Hemodynamics*
  • Humans
  • Hypotension
  • Ischemic Attack, Transient
  • Stents / adverse effects*
  • Stroke