The measurement of attenuation coefficient of some magnetic substances, to include diamagnetic: Cu, Zn, Ag, Te, Au, Pb, and Perspex; paramagnetic: Al, Ti, Mo, Dy, Ho, and Pt and ferromagnetic substances: Fe, Co, Ni, Gd, FeO, NiO, FeS, and Fe2O3, both in the presence and absence of an external magnetic field has been carried out using narrow beam transmission geometry by using gamma ray photons of incident energy 59.54keV from 100mCi, 241Am point source. It was observed very keenly that the value of linear attenuation coefficient of various substances mentioned above decreased remarkably. It varied in the range of 1-2%, 2-6% and 6-9% for diamagnetic, paramagnetic and ferromagnetic substances respectively in the presence of an external magnetic field. Measured results elucidated it very clearly that linear attenuation coefficient at H=0T, 0.6T and 1.2T continued to decrease with a regular increase of magnetic field. It is also manifested that measurements of linear attenuation coefficient is not affected with the change in thickness of the given substance. Within error limits (1-3%) variations are observed with increases of thickness along with magnetic field. Further to it the obtained results of linear attenuation coefficient without magnetic field (H=0T) were compared with theoretical data tables of FFAST and WinXCOM. It was established that values obtained are well within the experimental errors. To the best of our knowledge no other study in relation to the effect of linear attenuation coefficient in the presence of magnetic field available as precedence.
Keywords: Attenuation coefficient; External magnetic field; Magnetic substances.
Copyright © 2014 Elsevier Ltd. All rights reserved.