Self-expanding transcatheter aortic valve replacement using alternative access sites in symptomatic patients with severe aortic stenosis deemed extreme risk of surgery

J Thorac Cardiovasc Surg. 2014 Dec;148(6):2869-76.e1-7. doi: 10.1016/j.jtcvs.2014.07.020. Epub 2014 Jul 30.

Abstract

Objectives: The CoreValve Extreme Risk US Pivotal Trial enrolled patients with symptomatic severe aortic stenosis deemed unsuitable for surgical aortic valve replacement. Implants were attempted using transfemoral access (n = 489) or an alternative access (n = 150). In present analysis, we sought to examine the safety and efficacy of CoreValve transcatheter aortic valve replacement using alternative access.

Methods: The present study included 150 patients with prohibitive iliofemoral anatomy who were treated with the CoreValve transcatheter heart valve delivered by way of the subclavian artery (n = 70) or a direct aortic approach (n = 80). The echocardiograms were read by an independent core laboratory. The primary endpoint was all-cause mortality or major stroke at 12 months.

Results: The preoperative aortic valve area was 0.72 ± 0.27 cm(2) and mean aortic valve gradient was 49.5 ± 17.0 mm Hg. After the transcatheter aortic valve replacement, the effective aortic valve area was 1.82 ± 0.64 cm(2) at 1 month and 1.85 ± 0.51 cm(2) at 12 months. The mean aortic valve gradient was 9.7 ± 5.8 mm Hg at 30 days and 9.5 ± 5.7 mm Hg at 12 months. The death or major stroke rate was 15.3% at 30 days and 39.4% at 12 months. The individual rate of all-cause mortality and major stroke was 11.3% and 7.5% at 30 days and 36.0% and 9.1% at 12 months.

Conclusions: These data demonstrate that the CoreValve transcatheter heart valve delivered by an alternative access provides a suitable alternative for treatment of extreme risk patients with symptomatic severe aortic stenosis, who have prohibitive iliofemoral anatomy and no surgical options.

Trial registration: ClinicalTrials.gov NCT01240902.

Publication types

  • Controlled Clinical Trial
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aorta
  • Aortic Valve / physiopathology*
  • Aortic Valve Stenosis / complications
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation*
  • Cardiac Catheterization / mortality
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Humans
  • Male
  • Prospective Studies
  • Prosthesis Design
  • Severity of Illness Index
  • Stroke / etiology
  • Subclavian Artery
  • Time Factors
  • Treatment Outcome
  • United States

Associated data

  • ClinicalTrials.gov/NCT01240902