An ultra high performance liquid chromatography tandem mass spectrometry (U-HPLC-MS/MS) method was developed and validated to determine irbesartan (IRB) and hydrochlorothiazide (HCTZ) in human plasma simultaneously. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard losartan were separated on an Acquity U-HPLC BEH C18 column and mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the negative ion mode. The MRM transitions of m/z 427.2→206.9 and m/z 296.1→204.9 were used to quantify for IRB and HCTZ, respectively. The linearity of this method was found to be within the concentration range of 5-3000ng/mL for IRB, and 0.5-300ng/mL for HCTZ in human plasma, respectively. The lower limit of quantification (LLOQ) was 5ng/mL and 0.5ng/mL for IRB and HCTZ in human plasma, respectively. The relative standard deviations (RSD) of intra and inter precision were less than 12% for both IRB and HCTZ. The analysis time of per sample was 2.5min. The developed and validated method was successfully applied to a bioequivalence study of IRB (300mg) with HCTZ (12.5mg) tablet in Chinese healthy volunteers (N=20).
Keywords: Bioequivalence; Human plasma; Hydrochlorothiazide; Irbesartan; U-HPLC–MS/MS.
Copyright © 2014 Elsevier B.V. All rights reserved.