Background: The estimation of emphysematous changes is very sensitive to computed tomography (CT) threshold level. In clinical practice, the predetermined threshold is usually set at -950 Hounsfield units (HU) for the detection of low attenuation volume (LAV). However, threshold levels that are tightly connected to pulmonary function abnormalities have not been determined.
Purpose: To determine the threshold level for calculating an LAV that closely reflects airflow limitation in patients with chronic obstructive pulmonary disease (COPD).
Material and methods: Seventy-six consecutive non-COPD smokers and COPD patients underwent paired inspiratory and expiratory multidetector CT (MDCT). LAV% was segmented every 10 HU between -1000 and -750 HU to examine the correlation between LAV% and indexes of obstructive impairment.
Results: LAV% gradually increased as the threshold level increased on both inspiratory and expiratory images. LAV% on inspiratory images was higher than that on expiratory images at all threshold levels between -1000 and -750 HU. The threshold level that correlated with obstructive impairment differed between the two images: -930 HU on inspiratory and -870 or -880 HU on expiratory images.
Conclusion: LAV% dramatically changed according to the threshold level on both inspiratory and expiratory images, indicating that LAV% is dependent on the attenuation threshold level in patients with COPD. The threshold linking LAV% to airflow limitation was higher on expiratory than on inspiratory images.
Keywords: Chronic obstructive pulmonary disease; low attenuation volume; multidetector computed tomography; threshold.
© The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.