Background: Antenatal magnesium in preterm labor for neuroprotection decreases the incidence of cerebral palsy. However, there are no guidelines on the dose and duration of magnesium infusion for neuroprotection. As increased neonatal serum magnesium concentrations may be related to higher risk of morbidity and mortality, the role of total amount of magnesium and maternal serum magnesium concentrations associated with safe neonatal serum magnesium concentrations is not known.
Methods: A retrospective study was conducted on 289 mothers who received antenatal magnesium for neuroprotection as a loading dose of 4-6 g infused over 30 min, followed by a maintenance infusion of 1-2 g/h. Total magnesium dose infused to the mother and maternal serum magnesium concentrations were correlated with neonatal serum magnesium concentrations.
Results: Of the 289 mothers, 192 mother/baby dyads had all three measurements (maternal total magnesium dose, and maternal and neonatal serum magnesium concentrations). Magnesium infusion was continued beyond 24 h in 60 mothers. Total maternal magnesium dose at 24 and 48 h of infusion correlated with neonatal serum magnesium concentrations (r=0.55, P<0.0001 and r=0.35, P<0.0001, respectively), but not with maternal serum magnesium concentrations (r=0.004, P=0.98 and r=0.14, P=0.21). However, there was no correlation between the maternal and neonatal serum magnesium concentrations (r=0.10, P=0.15).
Conclusion: Total dose of magnesium infused to the mother correlates with neonatal serum magnesium concentrations. To keep neonatal serum magnesium concentrations within a range that is effective for neuroprotection and safe for the neonates, the total dose received by the mother needs to be monitored and limited.