Soft x-ray backlighting of direct-drive implosions using a spherical crystal imager on OMEGA

Rev Sci Instrum. 2012 Oct;83(10):10E501. doi: 10.1063/1.4728096.

Abstract

Using a spherically bent quartz crystal for the Si He(α) line at ~1.865 keV, a narrowband x-ray imager has been deployed at the Omega Laser Facility to record backlit images of direct-drive laser implosions. The crystal was cut along the 1011 planes for a 2d spacing of 0.687 nm, resulting in a Bragg angle of 83.9°. Apertures in front of the crystal were used to control the astigmatism of the imaging system. The backlit images show a high signal-to-background ratio of >10:1 with backlighter laser energies ≥1.5 kJ at a 10-ps pulse duration and a spatial resolution of better than 20 μm.