A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation)

J Am Coll Cardiol. 2012 Oct 9;60(15):1340-8. doi: 10.1016/j.jacc.2012.06.043. Epub 2012 Sep 19.

Abstract

Objectives: The goal of this study was to evaluate shorter duration (3 months) dual antiplatelet therapy (DAPT) after drug-eluting stent (DES) implantation.

Background: There have been few published reports of prospective randomized clinical studies comparing the safety and efficacy of shorter duration DAPT after DES implantation.

Methods: We randomly assigned 2,117 patients with coronary artery stenosis into 2 groups according to DAPT duration and stent type: 3-month DAPT following Endeavor zotarolimus-eluting stent (E-ZES) implantation (E-ZES+3-month DAPT, n=1,059) versus 12-month DAPT following the other DES implantation (standard therapy, n=1,058). We hypothesized that the E-ZES+3-month DAPT would be noninferior to the standard therapy for the primary composite endpoint (cardiovascular death, myocardial infarction, stent thrombosis, target\vessel revascularization, or bleeding) at 1 year.

Results: The primary endpoint occurred in 40 (4.7%) patients assigned to E-ZES+3-month DAPT compared with 41 (4.7%) patients assigned to the standard therapy (difference: 0.0%; 95% confidence interval [CI]: -2.5 to 2.5; p=0.84; p<0.001 for noninferiority). The composite rates of any death, myocardial infarction, or stent thrombosis were 0.8% and 1.3%, respectively (difference: -0.5%; 95% CI: -1.5 to 0.5; p=0.48). The rates of stent thrombosis were 0.2% and 0.3%, respectively (difference: -0.1%; 95% CI: -0.5 to 0.3; p=0.65) without its further occurrence after cessation of clopidogrel in the E-ZES+3-month DAPT group. The rates of target vessel revascularization were 3.9% and 3.7%, respectively (difference: 0.2%; 95% CI: -2.3 to 2.6; p=0.70).

Conclusions: E-ZES+3-month DAPT was noninferior to the standard therapy with respect to the occurrence of the primary endpoint. (REal Safety and Efficacy of a 3-month dual antiplatelet Therapy following E-ZES implantation [RESET]; NCT01145079).

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Angioplasty, Balloon, Coronary*
  • Coronary Angiography
  • Coronary Stenosis / diagnostic imaging
  • Coronary Stenosis / drug therapy*
  • Coronary Stenosis / surgery
  • Drug-Eluting Stents*
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Platelet Aggregation Inhibitors / therapeutic use*
  • Practice Guidelines as Topic*
  • Prospective Studies
  • Sirolimus / analogs & derivatives*
  • Sirolimus / pharmacology
  • Time Factors
  • Treatment Outcome
  • Withholding Treatment / standards*

Substances

  • Platelet Aggregation Inhibitors
  • zotarolimus
  • Sirolimus

Associated data

  • ClinicalTrials.gov/NCT01145079