Determination of benperidol and its reduced metabolite in human plasma by high-performance liquid chromatography and electrochemical detection

J Chromatogr. 1991 Apr 19;565(1-2):363-73. doi: 10.1016/0378-4347(91)80397-u.

Abstract

An isocratic high-performance liquid chromatographic method with electrochemical detection for the quantification of benperidol and its suggested reduced metabolite TVX Q 5402 in human plasma is described. The method included a two-step solid-phase extraction on reversed-phase and cation-exchange material, followed by separation on a cyanopropyl silica gel column (5 microns; 250 mm x 4.6 mm I.D.). The eluent was 0.15 M acetate buffer (pH 4.7) containing 25% acetonitrile (w/w). Spiperone served as internal standard. The inclusion of the cation-exchange step provided sample purity higher than those achieved with other methods. After extraction of 1 ml of plasma, concentrations as low as 0.5 ng/ml were detectable for both benperidol and the metabolite. In plasma samples collected from a schizophrenic patient treated with a single oral dose of 6 mg of benperidol, plasma levels of benperidol and of the metabolite could be measured from 20 min to at least 12 h after administration.

MeSH terms

  • Benperidol / analogs & derivatives*
  • Benperidol / blood*
  • Benperidol / pharmacokinetics
  • Chromatography, High Pressure Liquid / instrumentation
  • Chromatography, High Pressure Liquid / methods*
  • Electrochemistry
  • Humans

Substances

  • TVX Q 5402
  • Benperidol