A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method (LC-MS-MS) had been developed and validated for the quantitation of astragaloside IV (AGS-IV)-an active constituent of Radix Astragali in rat plasma. Assay method was developed by a series of operations described as below. The plasma proteins were precipitated with acetonitrile and digoxin was used as the internal standard (I.S.). The sample solution containing astragaloside IV and the I.S. were obtained and subsequently injected into a LC-MS-MS system following by a gradient elution at a slow flow rate combined with a valve diversion during the liquid chromatography. Chromatographic separation was achieved on a C4 (2.1 mmx10 mm) column with a gradient mobile phase comprised of 90% methanol in water and 10 mM ammonium acetate buffer. The analytes were detected with a PE Sciex API 3000 mass spectrometer using turbo ion spray with positive ionization. Ions monitored in the multiple reaction-monitoring (MRM) modes were m/z 785.5 (precursor ion) to m/z 143.2 (product ion) for AGS-IV and m/z 781.2 (precursor ion) to m/z 243.3 (product ion) for digoxin (I.S.). The method was validated over a linear range of 1-1000 ng/ml. The low limit of quantitation was 1.0 ng/ml. Results from a 3-day validation study demonstrated that the developed method possessed good precision (CV% values were between 5.9 and 7.6%) and accuracy (96.5-102.1%) across the calibration range. The recoveries were 91 and 90% for astragaloside IV and I.S., and no significant matrix effects were observed. QC samples were stable when kept at room temperature for 4 h, at -20 degrees C for 4 weeks, and after three freeze/thaw cycles.