Improved sensitivity of human immunodeficiency virus type 2 subtype B plasma viral load assay

J Clin Microbiol. 2005 Aug;43(8):4234-6. doi: 10.1128/JCM.43.8.4234-4236.2005.

Abstract

We developed a new assay for human immunodeficiency virus type 2 plasma RNA quantification based on a previous format. The new version performed significantly better than the original regarding the detection of subtype B, allowing the detection of 14 out of 36 plasma RNAs in the subtype B-infected patients not detected with the original version.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Automation
  • HIV-2 / classification*
  • HIV-2 / genetics
  • HIV-2 / isolation & purification*
  • Humans
  • RNA, Viral / blood*
  • Reproducibility of Results
  • Viral Load / methods*

Substances

  • RNA, Viral