Automated impedance cardiography (ICG) is an attractive method for noninvasive hemodynamic evaluation. The objective of our study was to evaluate the feasibility and diagnostic value automated ICG in patients with suspected coronary artery disease (CAD). We measured stroke index (SI) and cardiac index (CI) in 65 patients with suspected CAD at rest and during bicycle exercise testing. All patients underwent subsequent cardiac catheterization including coronary angiography (CA). Depending on the results of CA, patients were divided into three groups, patients without significant CAD (group 0), single vessel disease (group 1) or multivessel disease (group 2-3). In a subset of 20 patients, automated ICG was compared to measurements of CI by the thermodilution (TD) method.
Results: There were no significant differences in SI and CI at baseline between the three groups. At 75- and 100-watt exercise, patients in group 2-3 showed significantly lower mean values of SI and CI as compared to patients of group 0 and group 1 (all p < 0.05), indicating exercise-induced ischaemic left ventricular (LV) dysfunction. Three patients had to be excluded because of inappropriate quality of the ICG signals during exercise. Comparison of automated ICG with TD measurements of CI showed good correlations between both methods at rest (r = 0.73) and during exercise (r = 0.89-0.91).
Conclusions: We conclude that hemodynamic monitoring by automated ICG is both feasible and practical during exercise testing. Automated ICG can provide reliable and valuable additional diagnostic information on LV function during exercise which is helpful for selecting those patients for angiography who are likely to benefit from coronary interventions.