Correlation between magnetic resonance angiography (MRA) and quantitative coronary angiography (QCA) in ectatic coronary vessels

J Cardiovasc Magn Reson. 2004;6(1):17-23. doi: 10.1081/jcmr-120027801.

Abstract

Coronary artery ectasia (CAE) is defined as a dilatation of an arterial segment to a diameter at least 1.5 times that of the adjacent normal artery. The correct follow-up of ectatic vessels is hampered by the need for repeat angiograms. In this work we compared quantitative coronary angiography (QCA) measurements of the diameter of the proximal most ectatic part of coronary vessels, with corresponding measurements obtained by magnetic resonance angiography (MRA) using both gradient echo and turbo spin echo imaging sequences. Fifteen patients (14 male), aged 45-65 years, with known CAE were prospectively studied. Two electrocardiogram (ECG)-triggered pulse sequences were implemented for coronary magnetic resonance angiography. The first was a three-dimensional (3D), segmented, k-space gradient-echo sequence, employing a T2-weighted preparation prepulse and a frequency-selective, fat-saturation prepulse to enhance "white blood" (WB) contrast of the coronary arteries. The second sequence was an M2D dual Inversion Recovery (IR) Turbo Spin-Echo with a linear k-space acquisition scheme, providing "black-blood" (BB) contrast of the coronaries. All scans were carried out with the patient free breathing using a 2D, real-time Navigator beam, for respiratory motion tracking and gating. All patients underwent QCA, and the diameter of the proximal most ectatic part of each vessel was measured and compared with "white-blood" and "black-blood" MRA measurements. The average length of continuously visualized LM, LAD, LCx, and RCA by MRA was 2.5 +/- 0.3, 5.8 +/- 0.8, 3.9 +/- 1.0, and 7.2 +/- 1.2 cm, respectively. There were no statistically significant differences between diameter measurements of the proximal most ectatic part of each vessel, obtained with WB and BB sequences. There was a close correlation between MRA and QCA measurements (r = 0.87, p < 0.001). Bland-Altman analysis showed no systematic differences between the examined methods, over the whole range of vessel diameters measured. Coronary MRA is in close correlation with QCA for CAE detection. Magnetic resonance angiography, being noninvasive, may prove of significant value for the efficient follow-up of these patients.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Coronary Angiography*
  • Coronary Artery Disease / diagnosis*
  • Coronary Vessels / pathology*
  • Dilatation, Pathologic / diagnosis
  • Female
  • Follow-Up Studies
  • Humans
  • Magnetic Resonance Angiography*
  • Male
  • Middle Aged
  • Prospective Studies
  • Radiographic Image Enhancement
  • Statistics as Topic