A new automated method for the assay of guanidinoacetic acid (GAA) in dried blood spot (DBS) on filter paper is reported. The method, based on reversed-phase (RP)-HPLC, precolumn derivatisation with benzoin and fluorescence detection, has shown good precision and sensitivity and requires only minimal sample handling. The validity of the method was demonstrated by analysing the neonatal blood spot of a patient affected by guanidinoacetate methyltransferase (GAMT) deficiency. GAA concentration was found to be nearly 12-fold higher than the mean control value. We propose this method as an inexpensive and widely applicable tool for the diagnosis of GAMT deficiency.